Features:
The
products are used in solar water heater, the temperature difference and
temperature to control the output.
It is provided with two output
control, temperature difference control two temperature zone.
When the
temperature reaches the set value, it automatically runs the water pump
circulation and makes the two temperature zone temperature equilibrium.
The other channel controls electric heating, when the solar heating
failed to reach the set temperature, the electric heating system can
automatically start and heat to the set temperature.
It will control heating system and automatically makes water temperature
stay in temperature deference range.
Specifications:
Power Consumption: less than 3W
Heating Control Range: 2 celsius ~99 celsius
Temp. Difference Start Control: 3 celsius ~50 celsius
Resolution: 1 celsius
Precision: +1 celsius
Input Signal: 2channel sensor, 20KX2MX2
Size: 76*76*35mm2.99*2.99*1.37in
Operating Temperature: 10 celsius ~50 celsius
Operating Humidity: RH less than 90percent
Light
Function
Setting Range
Default
Unit
#1
temperature difference start
stop pump temperature difference
+1~50
5
celsius
#1, #2
stop pump temperature difference
1~temperature difference start1
2
celsius
#2
temperature return difference
1~20
5
celsius
#3
high temperature correction
10~10
0
celsius
#4
low temperature correction
10~10
0
celsius
Package Includes:
1 x Temperature Controller
2 x Sensor Probes
.
The products are used in solar water heater, the temperature difference and temperature to control the output
It is provided with two output control, temperature difference control two temperature zone
When the temperature reaches the set value, it automatically runs the water pump circulation and makes the two temperature zone temperature equilibrium
The other channel controls electric heating, when the solar heating failed to reach the set temperature, the electric heating system can automatically start and heat to the set temperature
It will control heating system and automatically makes water temperature stay in temperature deference range