Feature:
1. Easy Operation: The proportional pump can be directly installed on the water supply pipeline, which is powered by water pressure, no need power on or motor startup.
2. Reasonable Design: With air release valve, the air of the proportioner can be automatically released. Super large diameter ensures faster work. External adjustment is flexible and convenient.
3. Precise Scale: With accurate scale, the proportion of liquid and additive can be precisely adjusted to achieve the best effect.
4. Stable Proportion: The dosing ratio is not affected by water flow pressure, the amount of solution injected is proportional to the amount of water flowing into the pipeline.
5. Perfect Dosing: Complete quantitative dosing and mixing function, continuous proportional injection, accurate proportion tracking and adjustment, automatic uniform dilution.
Specification:
Item Type: Proportional Pump
Material: Plastic
Interface Size: Male Thread G3/4
Water Flowing Temperature: 4-30 celsius
Note: The accessory color is random
Application:
For livestock and poultry breeding:
1. The type and dosage of drugs can be changed at any time.
2. It is convenient and quick to add drugs in case of emergency.
3. Self prepare solution and add it to the channel to clean drinking water, livestock and poultry water pipelines.
4. Solve the problem of sedimentation and pollution in the water storage tank.
5. Automatic spraying system, replacing the water tank.
6. Easy cleaning of water pipes and sinks, cleaning of water networks, odor treatment, equipment maintenance, conveyor belt cleaning, livestock and poultry drinking water treatment, acidification treatment.
Purpose: Agricultural irrigation, equipment maintenance, horticulture and flowers, animal husbandry, environmental water treatment, industrial, car washing foam, food processing, industrial hygiene, printing and other industries that need constant dilution
Installation and Fixing:
1. Location Selection: The water inlet and outlet of the proportional pump must be consistent with the water inlet and outlet of the main pipe.
2. The proportional pump must be installed with the proportional pump above and the liquid suction pipe below.
3. Fix the proportional pump to the wall or other facilities.
4. Install the water inlet and outlet of the proportional pump according to the water flowing direction to ensure their airtightness.
5. Install 100-120 mesh filter between the water valve and the inlet of the proportional pump.
6. When dosing is required, close the side branch valve of the proportional pump and open the valve on both sides of the proportional pump to feed.
7. When the proportional pump starts to work, a click will be heard. At this time, press the air release valve on the top of the proportional pump, and release it when a small amount of water flows out to ensure the normal operation of the dosing device.
Scale Adjustment:
Proportional pump can adjust the proportion of additives in the injected water flowing according to the actual situation, so as to achieve the best effect of additives.
The specific methods are as follows:
1. Loosen the screws and remove the U shaped adjusting lock from the upper part of the proportional pump.
2. Preset the proportion of liquid additives and water according to the proportion of water scale on the proportional pump:
The counterclockwise adjustment increases the specific gravity of the liquid additive. The clockwise adjustment is to reduce the specific gravity of the liquid additive.
The percentage on the proportional pump is calculated according to the final water outlet of the proportional pump being 100.
3. Turn the adjuster until the hole above the U shaped adjusting lock is inserted into the slot of the proportional pump.
4. Press the U shaped adjusting lock into the upper slot of the proportional pump until it is fastened..
Package List:
1 x Proportional Pump1 x Drug Suction Pipe With Filter5 x Gasket1 x Bracket1 x Wrench1 x Manual
Note:
1. When using the automatic proportional pump, ensure that the container containing liquid additives is not empty!2. Vent Valve: At the beginning of starting the proportional pump, press and hold the vent valve down for a few seconds to discharge the existing air out of the interior. In this process, a little water will flow out. After the air is discharged, close the vent valve quickly.3. During installation and use, ensure that filtering equipment must be installed at the inlet end of the proportional pump.4. If the working resistance increases during use, add lubricating oil to the piston to increase its service life.5. After use, clean the pump with clean water to reduce corrosion and prolong the service life of the proportional pump.